What is the session disconnect timeout for a PCoIP session?
Answer: A PCoIP protocol session is disconnected after a period of network inactivity that is dependent on the client type and configuration settings. This includes settings for: PCoIP Zero Clients: 30 seconds (default) of no network communication PCoIP …
What causes a firmware upgrade failure?
Problem Uploading firmware through the AWI or a PCoIP Zero Client or PCoIP Remote Workstation Card fails with an error message. Applying firmware through the PCoIP Management Console fails.   Cause and Solution There are multiple scenarios that can cause …
How can I change USB authorizations for PCoIP Zero Client?
USB devices can be enabled or disabled which allows IT control of the use of peripherals with HP Anyware PCoIP Agent, VMware Horizon View using PCoIP protocol, or PCoIP Remote Workstation Cards. PCoIP Zero Clients provide unique USB security features that …
How do I Set Zero Client password in PCoIP Management Console?
Use PCoIP Management Console PCoIP Management Console is recommended to manage the password setup for zero clients, including enabling the password protection for OSD and AWI, setting the password, and whether or not hiding the Password options from OSD …
Session negotiation failed while connecting from Zero Client to HP Anyware. The PCoIP Zero Client may not be compatible with the host session negotiation cipher setting.
Problem When trying to connect to a HP Anyware PCoIP Agent you receive the error "Session negotiation failed. The PCoIP Zero Client may not be compatible with the host session negotiation cipher setting."   Cause The PCoIP Zero Client session connection …
Where can I find a PCoIP-compatible connection broker?
In additional to HP Anyware Manager, as part of the Technology Partner Program, HP Anyware enables companies to build support for PCoIP session brokering. The following is a list of PCoIP compatible connection brokers:   Company Product Compatible with …