What are the cabling requirements in a Remote Workstation Card environment?
Answer: HP Anyware PCoIP Remote Workstation Cards and PCoIP Zero Clients are designed considering port pass through and should be connected in a specific manner to limit potential display issues. In a PCoIP workstation environment ensure the connection …
Why does the PCoIP Zero Client OSD image quality preference slider not have any effect on PCoIP session?
Answer: Activation of the  Image Quality Preference slider requires enablement of the  check box found in the  Configure PCoIP image quality levels  ADM GPO variable shown below.   The Image Quality Preference slider (shown below) resides in the OSD under …
Should I configure "Maximum Initial Image Quality" to 100 if I want lossless still image?
No. Regardless of PCoIP image-quality settings, still images are always lossless. The time it takes to display them depends on your image-quality settings and available network bandwidth. For most situations, it is recommended to use 40 for Minimum Image …
Why do I see black bars on the side or bottom of my display when connecting to a zero client?
Scenario : When connecting a display (TV or monitor) to a PCoIP zero client you get solid black bars at the top and bottom or left and right sides of the display. It appears as if the image is being cut off. Resolution : This issue is caused by ' …
How can I tell which monitors are connected and if a USB device is connected locally or bridged on a PCoIP Zero Client?
Answer: From your Web browser, enter the IP address of your PCoIP Zero Client. Log in to the user interface with your user credentials. (Note: Depending on your specific setup, a password may not be required.) From the Info menu, select Attached Devices . …
Why do certain large screen (>27" monitors) dual-link DVI monitors not work with the TERA 2 PCoIP Zero Clients?
Scenario When some monitors supporting 2560 x 1600 and 2560 x 1440 resolutions are power cycled with the power switch, the video may not appear when connected to a Tera2 Zero Client via dual-link DVI. This applies to: Tera2 Zero Clients running firmware …
Recovering the OSD when the resolution was set to 800x600 or lower which removed functionality.
This occurs because these low resolutions do not display the OSD correctly, and access to some configurations are lost. Previously this was not an available feature which prevented devices being put into un-configurable states by setting resolutions to …
Could the use of two DVI channels be a sources for delay which might cause jitter in a PCoIP Remote Workstation Card configuration?
Using the two DVI channels on a PCoIP Zero Client to PCoIP Remote Workstation Card with the Dual-link DVI connector converter to achieve a 2560x1600 resolution is NOT a source for delay which might cause jitter. The use of two DVI channels could be one of …