Why my HP anyware Connector (CACv2) does not connect after the recent Ubuntu 18.04 OS Nov-13-2019 Update?
The latest patch release of Ubuntu 18.04 (Nov-13 patch) will break CAM CACv2 connectivity. Affected Ubuntu 18.04 OS patch version: Nov-13-2019 release:  ubuntu-1804-bionic-v20191113 ubuntu-os-cloud ubuntu-1804-lts Recommendation: If you experience this …
How do I change the FQDN (Fully Qualified Domain Name) of a PCoIP Zero Client?
First, change the PCoIP name to a new name. Currently, the "PCoIP Device Name" can only be changed on an individual basis in two locations: The  "OSD--> Configuration--> Label"  tab The  "AWI--> Configuration--> Label"  tab The default format is  …
Management Console profile is not applied to the Remote Workstation Card
Applying a Profile to a Remote Workstation Card from PCoIP Management Console will be unsuccessful if the Enable Audio setting on the Remote Workstation Card has never been enabled (default is disabled) or the Remote Workstation Card has not had the …
Local Administrative Password setting is disabled after changing the firmware version in the profile in the PCoIP Management Console 3.0.0
Problem After changing the firmware version in a profile in PCoIP Management Console 3.0.0 the Local Administrative Password setting is no longer enabled and the password field is blank.   Cause This issue is known to happen when the following conditions …
Error Failed to find anything in domain DN when installing HP Anyware Connector
ERROR Failed to find anything in domain DN   Issue: When trying to install HP Anyware Connector you receive the error "ERROR Failed to find anything in domain DN: dc=172,dc=31,dc=18,dc=194" (note that the ip in the error will not be the same). The most …
Recovering the OSD when the resolution was set to 800x600 or lower which removed functionality.
This occurs because these low resolutions do not display the OSD correctly, and access to some configurations are lost. Previously this was not an available feature which prevented devices being put into un-configurable states by setting resolutions to …
Could the use of two DVI channels be a sources for delay which might cause jitter in a PCoIP Remote Workstation Card configuration?
Using the two DVI channels on a PCoIP Zero Client to PCoIP Remote Workstation Card with the Dual-link DVI connector converter to achieve a 2560x1600 resolution is NOT a source for delay which might cause jitter. The use of two DVI channels could be one of …
What does GSOAP :tera_gsoap_tls_shutdown: tera_rtos_event_get timeout mean in the log?
Problem Message GSOAP :tera_gsoap_tls_shutdown: tera_rtos_event_get timeout is found in host or client log file.   Cause GSOAP is the protocol used by the PCoIP Management Console 1.x. This error is caused by a socket being opened by GSOAP and not closed …