Should I configure "Maximum Initial Image Quality" to 100 if I want lossless still image?
No. Regardless of PCoIP image-quality settings, still images are always lossless. The time it takes to display them depends on your image-quality settings and available network bandwidth. For most situations, it is recommended to use 40 for Minimum Image …
Why can I use my cell phone to transfer files when I have blocked all mass storage devices through the Unauthorized Devices table?
There are 3 ways to transfer data to USB devices. Mass storage devices (flash drives, DVD), all file types Photo Transfer Protocol - PTP - still image capture device class for cameras, (pictures). Media Transport Protocol - MTP - (smartphones), all file …
Requirements for the Leostream broker to automatically detect a PCoIP Remote Workstation Card?
Requirements For the Leostream broker to automatically detect a Remote Workstation Card the following components must be installed: PCoIP Remote Workstation Card inserted in the host PC Leostream Connection Broker 7.7 or newer Leostream Agent 5.5.95 or …
Is the current Texas Instruments USB to serial adapter in the Samsung NC241 compatible with View 5.0?
Answer: No, the current Texas Instruments USB to serial adapter built in to the Samsung NC241 is not compatible with View 5.0, or with the latest TI drivers. For View 5.0 an older legacy driver must be used. This driver must be obtained directly from …
Why do I see black bars on the side or bottom of my display when connecting to a zero client?
Scenario : When connecting a display (TV or monitor) to a PCoIP zero client you get solid black bars at the top and bottom or left and right sides of the display. It appears as if the image is being cut off. Resolution : This issue is caused by ' …