Troubleshooting PCoIP session Connection Issues.
Problem When connecting to a PCoIP Standard Agent for Windows, PCoIP Graphics Agent for Windows, PCoIP Standard Agent for Linux or PCoIP Graphics Agent for Linux the connection fails with one of the following messages: Error: Unable to connect to …
Troubleshooting session disconnections
Problem PCoIP sessions are getting disconnected for no apparent reason. PCoIP session disconnections can be random events, occur after a certain time has elapsed or impact all PCoIP sessions at once or just one PCoIP session, either way they are …
How to use the HP Anyware Licensing Portal
The HP Anyware Licensing Portal provides secure access to the list of licenses and can be used by the company's assigned Account Administrator. The Account Administrator role can be fulfilled by one central administrator or can be distributed across …
Host Session Health Check - Diagnostics and troubleshooting guide
Summary To receive a detailed host diagnostic report, create a host  support/log file bundle  and then submit this bundle to the PCoIP  health check   tool.  Once the files are submitted, it will take 5-10 minutes to produce a detailed report.  The report …
Where can I find a PCoIP-compatible connection broker?
In additional to HP Anyware Manager, as part of the Technology Partner Program, HP Anyware enables companies to build support for PCoIP session brokering. The following is a list of PCoIP compatible connection brokers:   Company Product Compatible with …
How do I check for packet loss on the ESX interface?
If there is packet loss on a PCoIP protocol session, but an analysis of network devices in the path show no loss and they have been properly configured (see  Network session checklist for PCoIP protocol LAN and WAN deployments ) then you may want to …
What is the session disconnect timeout for a PCoIP session?
Answer: A PCoIP protocol session is disconnected after a period of network inactivity that is dependent on the client type and configuration settings. This includes settings for: PCoIP Zero Clients: 30 seconds (default) of no network communication PCoIP …
Why is the host PC on my VMware Horizon brokered Remote Workstation Solution unable to wake up?
Scenario When a View Connection Server brokers a workstation connection between a PCoIP Zero Client and a PCoIP Remote Workstation Card, and the host is put into any low power state (sleep, hibernate or shutdown); the client is unable to wake the host and …
PCoIP TROUBLESHOOTING STEPS: VMware View Virtual desktop performance
This article provides a brief list of general troubleshooting steps for performance issues on virtual desktops. Scenarios covered include: Video slicing or tearing. Screen (or parts of the screen) becomes fuzzy screen and then clears up. Slow screen …