What is monitor emulation on the PCoIP Remote Workstation Card and how does it work?
Answer: Monitor emulation is a feature on the PCoIP Remote Workstation Card (also known as a host card) that ensures graphics cards see a valid EDID on a Display Port or DVI port on boot. This helps prevent the graphics card from driving DVI signals or DP …
Can multi-factor authentication be used with PCoIP?
Multi-factor authentication systems are supported by Teradici Products. Examples of multi-factor authentication systems are RSA SecurID and Duo. HP Anyware Manager supports multi-factor authentication as secondary authentication via a radius server.  …
How can I identify the version of VMware's SVGA driver in my virtual machine?
Answer: To identify the VMware SVGA driver version that your current virtual machine is using perform the following steps. Log in to your VM. Left click the start button. Right click Computer. Left click Manage. Left click Device Manager. Expand Display …
Why are my displays not displaying the virtual desktop properly (how do I calculate VRAM)?
Problem Your VMware View virtual machine is showing a blank screen because the virtual machine does not have enough video memory.   Resolution Ensure that your virtual machine (VM) has enough VRAM to support a one or two monitor combined resolution, …
How do I enable NTP on PCoIP Zero Clients and PCoIP Remote Workstation Cards?
Enabling NTP is important on the PCoIP Zero Client and PCoIP Remote Workstation Card. NTP is using for the following: Setting the time and date of the PCoIP Zero Client and PCoIP Remote Workstation Card. As there is no battery on the devices, the time and …
I can't see or access PC/workstation BIOS when using a PCoIP Remote Workstation Card?
Problem When remotely access my a workstation using the PCoIP Remote Workstation Card, the BIOS is not visible remotely and when it is, can't be controlled.   Cause In order to access the BIOS when using a PCoIP Remote Workstation Card, the USB function …
How do I enable and disable the PCoIP Zero Client session disconnect CTRL-ALT-F12 key sequence?
Enable When using a PCoIP Zero Client to connect to HP Anyware, Amazon Workspaces or VMware Horizon View the Ctrl-Alt-F12 shortcut is enabled by default. This setting can be configured via the AWI or PCoIP Management Console. When using a workstation with …
How do I reset the configuration parameters entered on my PCoIP Zero Client or PCoIP Remote Workstation Card?
Answer: There are four ways to reset the PCoIP Zero Client to default settings which are described below. The PCoIP Remote Workstation card (also known as a PCoIP host card) has one reset procedure also described below. Some network information will be …
Why am I experiencing poor performance when playing a 1080p high fps video with my PCoIP Remote Workstation Card and PCoIP Software Client?
Problem When using the PCoIP Software Client to connect to a PCoIP Remote Workstation Card I cannot achieve high frame rate playback.   Cause There are a number of factors that can contribute to poor performance so the best method of trying to determine …