Can I connect a local monitor to computer that has PCoIP Remote Workstation Card or HP Anyware Installed?
Although you may have enough display heads on your GPU to connect local monitors, it is not a supported configuration when using a PCoIP Remote Workstation Card or HP Anyware. Connecting an additional local monitor may cause the following issues: Blank …
What is the impact of minimum and maximum initial image quality on a PCoIP Session?
Minimum and maximum initial image quality sets the lower and upper quality level. The default values in HP Anyware is Q40 for the minimum initial image quality and Q80 for the maximum initial image quality. If PCoIP estimates there is adequate bandwidth …
Should I use an initial image quality of Q100?
An initial image quality of Q100 will deliver the highest quality of image PCoIP can deliver. Q100 is not lossless, for a lossless image, build to lossless must be enabled.  How to configure the Turn off Build-to-Lossless feature session variable in GPO …
When does the PCoIP Management Console apply a resolution change using the Enable Preferred Resolution Override setting while in a PCoIP session?
In PCoIP Management Console (MC) 1.9.1 (and newer), PCoIP Zero Clients with firmware 4.1.2 (and newer) can be configured to override the attached monitors native resolution using the Enable Preferred Resolution Override feature. The setting is recognized …
Why does the PCoIP Zero Client OSD image quality preference slider not have any effect on PCoIP session?
Answer: Activation of the  Image Quality Preference slider requires enablement of the  check box found in the  Configure PCoIP image quality levels  ADM GPO variable shown below.   The Image Quality Preference slider (shown below) resides in the OSD under …
Core API - PCoIP Client SDK for Linux
Core API Change Log This section outlines API call updates and changes for the Core API from the different versions of the PCoIP Client SDK for Linux.   20.10 PcoipClientInitData PcoipClientInitData structure has been changed for licensing related data. …
Core API - PCoIP Client SDK for Windows
Core API Change Log This section outlines API call updates and changes for the Core API from the different versions of the PCoIP Client SDK for Windows.   20.10 PcoipClientInitData PcoipClientInitData structure has been changed for licensing related data. …
Should I configure "Maximum Initial Image Quality" to 100 if I want lossless still image?
No. Regardless of PCoIP image-quality settings, still images are always lossless. The time it takes to display them depends on your image-quality settings and available network bandwidth. For most situations, it is recommended to use 40 for Minimum Image …
Core API - PCoIP Client SDK for macOS
Core API Change Log This section outlines API call updates and changes for the Core API from the different versions of the PCoIP Client SDK for macOS. 20.10 PcoipClientInitData PcoipClientInitData structure has been changed for licensing related data. The …