PCoIP Zero Client refuses to connect to a View Connection Server
This is a common issue we run into especially when we depreciate older security components from our firmware. We ran into this issue when we depreciated TLS1.0 and are once again seeing it mow that we have depreciated TLS1.1 The typical message the user …
Unable to connect (0x1001) when a PCoIP Zero Client tries to connect to a PCoIP Remote Workstation Card
Problem When a PCoIP Zero Client is trying to connect to a PCoIP Remote Workstation Card. Clicking the connection button on the PCoIP Zero Client, the error message "Unable to connect (0x1001). Please contact your IT administrator" is returned   Cause The …
What is the session disconnect timeout for a PCoIP session?
Answer: A PCoIP protocol session is disconnected after a period of network inactivity that is dependent on the client type and configuration settings. This includes settings for: PCoIP Zero Clients: 30 seconds (default) of no network communication PCoIP …
Error: The Certificate for the Domain Controller is Untrusted or Invalid
Problem   When connecting to a HP Anyware PCoIP Agent the client receives the error "The Certificate for the Domain Controller is Untrusted or Invalid."     Causes:   The error generally means that the HP Anyware Connector was unable to communicate with …
How can I shadow a VMware Horizon View PCoIP desktop session from my vSphere console?
Note: This knowledge base article does not apply to HP Anyware. HP Anyware uses a  Anyware software GPU or a hardware GPU disabling the vSphere Console. In some cases viewing a remote users PCoIP session may be beneficial to troubleshooting an issue. In …
How do I Set Zero Client password in PCoIP Management Console?
Use PCoIP Management Console PCoIP Management Console is recommended to manage the password setup for zero clients, including enabling the password protection for OSD and AWI, setting the password, and whether or not hiding the Password options from OSD …