What do the PCoIP Zero Client session connection failure codes mean?
Session connection error messages--such as "Unable to connect (0x1000). Please contact your IT administrator."--are described below.  0x1000: Session lost. MGMT_UI :No PCoIP data received in the past 3 seconds (connection to peer might be lost) MGMT_SYS …
Troubleshooting session disconnections
Problem PCoIP sessions are getting disconnected for no apparent reason. PCoIP session disconnections can be random events, occur after a certain time has elapsed or impact all PCoIP sessions at once or just one PCoIP session, either way they are …
Unable to connect (0x1001) when a PCoIP Zero Client tries to connect to a PCoIP Remote Workstation Card
Problem When a PCoIP Zero Client is trying to connect to a PCoIP Remote Workstation Card. Clicking the connection button on the PCoIP Zero Client, the error message "Unable to connect (0x1001). Please contact your IT administrator" is returned   Cause The …
What does "No Available Hosts for Connection" mean?
The message "No Available Hosts for Connection" appears if the PCoIP Zero Client has enabled the Host Discovery feature and tries to establish a session but cannot find a PCoIP Remote Workstation Card that is not currently in a session on the network. If …
What does the error message "Session Closed Remotely" mean?
There are a number or reasons that the message "Session Closed Remotely" appears during a brokered session listed below. Informational Messages Closed by login at an alternate location or host shutdown/restart User initiated logout Disconnected by …
Are there any limitations on physical distance for a PCoIP session?
Due to the design of PCoIP, using UDP for data transmission, PCoIP will operate over vast distances and network latencies up to 250 ms. PCoIP intelligently acknowledges the traffic inside the protocol allowing for high speed transmission over high latency …
How do I configure a Peer-to-Peer Connection between a PCoIP Zero Client and a PCoIP Remote Workstation Card?
Requirements This article describes the configuration of a peer-to-peer, or dedicated connection between a PCoIP Zero Client and a PCoIP Remote Workstation Card including dual and quad display scenario's. Single or dual display requires a single PCoIP …
Why does my PCoIP Remote Workstation hibernate or sleep and not power off remotely from my Tera 2 PCoIP Zero Client?
When a PCoIP Zero Client attempts to power down a Windows 7 or Windows 10 workstation host during a PCoIP session, the workstation may enter the sleep state rather than being shutdown. This will occur if Windows is configured to map the PC power button to …