PCoIP Remote Workstation Card Software does not install on host.
When the PCoIP Remote Workstation Card Software does not detect a PCoIP Remote Workstation Card, it generates the following error and installation stops.   No PCoIP devices detected. Please ensure the hardware is installed and the Host Driver Function is …
Management Console profile with blacklisted ciphers fails to apply to Remote Workstation Card
If a Management Console profile is configured to blacklist any of the following Remote Workstation Card ciphers, the profile application will fail on Remote Workstation Cards running firmware 21.01 or newer. TLS_RSA_WITH_AES_256_GCM_SHA384 …
Why are some resolutions not available in the OSD but are listed as available in the PCoIP Zero Client Administrator's Guide?
This article is applicable to PCoIP Zero Clients that have DVI ports. To see all the supported resolutions in the OSD as listed in the PCoIP Zero Client Administrators' Guide ( GUI Reference > Configuring OSD Display Settings > OSD Dual-display: Display …
Vault Backup fails if secret has been deleted
Problem The vault backups fail for Anyware Manager if the secret data is deleted. To Verify: Install Anyware Manager Complete the initial login and create a deployment. Create a Deployment Service account and then delete it (this is what might trigger the …
Anyware Connector Health check - Diagnostics and troubleshooting guide
Summary To receive a detailed  Anyware Connector diagnostic report, create a Anyware Connector  support/log file bundle  and then submit this bundle to the PCoIP  health  check tool .  Once the files are submitted, it will take 5-10 minutes to produce a …
Mobile Devices (Tablets)
Mobile Devices (Tablets)   Android Unable to establish Windows Graphics Session with an Android Client iOS How to get logs from iOS Windows IoT     Android Unable to establish Windows Graphics Session with an Android Client  Workaround:   Soft Client on …
PCoIP Connection Manager Health check - Diagnostics and troubleshooting guide
Summary To receive a detailed  PCoIP Connection Manager diagnostic report, create a PCoIP Connection Manager  support/log file bundle  and then submit this bundle to the PCoIP  health  check tool .  Once the files are submitted, it will take 5-10 minutes …
Securing PCoIP Zero Clients to Remote Workstation Cards
When securing PCoIP Zero Clients to Remote Workstation Cards, it is recommended that security conscious customers use the  Suite B: TLS 1.2 with Suite B-compliant 192-bit elliptic curve encryption TLS Security Mode. This will require customers have the …