Why does touchscreen calibration not work with a resolution other then native resolution?
Answer: Calibration for touchscreens via Teradici PCoIP firmware is designed to work from the OSD in native resolution with elo branded touch screens. To calibrate from a different resolution other than native, the elo device must be bridged and the elo …
Can I connect a local monitor to computer that has PCoIP Remote Workstation Card or HP Anyware Installed?
Although you may have enough display heads on your GPU to connect local monitors, it is not a supported configuration when using a PCoIP Remote Workstation Card or HP Anyware. Connecting an additional local monitor may cause the following issues: Blank …
Do PCoIP Zero Clients and PCoIP Remote Workstation Cards support HDMI connections?
PCoIP zero clients only come with the following connections: sVGA DVI (single and dual link) Display Port (1.1a) HDMI is not a supported connector type on PCoIP Zero Clients. You can purchase Display Port or DVI to HDMI cables and adapters however you may …
What is the impact of minimum and maximum initial image quality on a PCoIP Session?
Minimum and maximum initial image quality sets the lower and upper quality level. The default values in HP Anyware is Q40 for the minimum initial image quality and Q80 for the maximum initial image quality. If PCoIP estimates there is adequate bandwidth …
Should I use an initial image quality of Q100?
An initial image quality of Q100 will deliver the highest quality of image PCoIP can deliver. Q100 is not lossless, for a lossless image, build to lossless must be enabled.  How to configure the Turn off Build-to-Lossless feature session variable in GPO …
What are the cabling requirements in a Remote Workstation Card environment?
Answer: HP Anyware PCoIP Remote Workstation Cards and PCoIP Zero Clients are designed considering port pass through and should be connected in a specific manner to limit potential display issues. In a PCoIP workstation environment ensure the connection …
Should I configure "Maximum Initial Image Quality" to 100 if I want lossless still image?
No. Regardless of PCoIP image-quality settings, still images are always lossless. The time it takes to display them depends on your image-quality settings and available network bandwidth. For most situations, it is recommended to use 40 for Minimum Image …
Could the use of two DVI channels be a sources for delay which might cause jitter in a PCoIP Remote Workstation Card configuration?
Using the two DVI channels on a PCoIP Zero Client to PCoIP Remote Workstation Card with the Dual-link DVI connector converter to achieve a 2560x1600 resolution is NOT a source for delay which might cause jitter. The use of two DVI channels could be one of …
Why are some resolutions not available in the OSD but are listed as available in the PCoIP Zero Client Administrator's Guide?
This article is applicable to PCoIP Zero Clients that have DVI ports. To see all the supported resolutions in the OSD as listed in the PCoIP Zero Client Administrators' Guide ( GUI Reference > Configuring OSD Display Settings > OSD Dual-display: Display …