Why does HP Anyware specify a Nvidia and AMD driver for use with the PCoIP Graphics Agent?
HP Anyware performs extensive testing of the PCoIP Graphics Agent for Windows and the PCoIP Graphics Agent for Linux before release. As part of the tests, HP Anyware uses the latest Nvidia and AMD drivers available at the time. Upon release of the PCoIP …
Can I connect a local monitor to computer that has PCoIP Remote Workstation Card or HP Anyware Installed?
Although you may have enough display heads on your GPU to connect local monitors, it is not a supported configuration when using a PCoIP Remote Workstation Card or HP Anyware. Connecting an additional local monitor may cause the following issues: Blank …
What is the impact of minimum and maximum initial image quality on a PCoIP Session?
Minimum and maximum initial image quality sets the lower and upper quality level. The default values in HP Anyware is Q40 for the minimum initial image quality and Q80 for the maximum initial image quality. If PCoIP estimates there is adequate bandwidth …
Should I use an initial image quality of Q100?
An initial image quality of Q100 will deliver the highest quality of image PCoIP can deliver. Q100 is not lossless, for a lossless image, build to lossless must be enabled.  How to configure the Turn off Build-to-Lossless feature session variable in GPO …
Should I configure "Maximum Initial Image Quality" to 100 if I want lossless still image?
No. Regardless of PCoIP image-quality settings, still images are always lossless. The time it takes to display them depends on your image-quality settings and available network bandwidth. For most situations, it is recommended to use 40 for Minimum Image …