Do PCoIP Zero Clients and PCoIP Remote Workstation Cards support HDMI connections?
PCoIP zero clients only come with the following connections: sVGA DVI (single and dual link) Display Port (1.1a) HDMI is not a supported connector type on PCoIP Zero Clients. You can purchase Display Port or DVI to HDMI cables and adapters however you may …
Why does the dual-link DVI monitor connected to my PCoIP Zero Client not display properly?
Check your DVI cable, it may not be dual-link capable. Dual-link cable ends have all of the pins populated whereas single-link cables are missing 6 pins. These pins carry the extra information to allow up to 2560 x 1600 resolution. Some monitors will …
Why do my PCoIP Zero Client image settings have no effect when I change them?
Problem When connecting to your HP Anyware PCoIP Agent or VMware Horizon VM you may notice that the PCoIP Zero Client imaging settings have no effect on the PCoIP Session. The pcoip_server log file and the PCoIP Zero Client AWI both indicate the imaging …
Encryption and bandwidth metrics used for various setups PCoIP Devices and VMware Horizon View
Answer:   Encryption and Bandwidth Metrics   Tera1 Zero Client Tera2 Zero Client Windows View Client Host Card No View Security Server Up to 220 Mbps AES-128 (not encapsulated) Up to 500 Mbps AES-128/AES-256| (not encapsulated/encapsulated) FW 4.1.0 and …
Should I use an initial image quality of Q100?
An initial image quality of Q100 will deliver the highest quality of image PCoIP can deliver. Q100 is not lossless, for a lossless image, build to lossless must be enabled.  How to configure the Turn off Build-to-Lossless feature session variable in GPO …
When does the PCoIP Management Console apply a resolution change using the Enable Preferred Resolution Override setting while in a PCoIP session?
In PCoIP Management Console (MC) 1.9.1 (and newer), PCoIP Zero Clients with firmware 4.1.2 (and newer) can be configured to override the attached monitors native resolution using the Enable Preferred Resolution Override feature. The setting is recognized …
Why does the PCoIP Zero Client OSD image quality preference slider not have any effect on PCoIP session?
Answer: Activation of the  Image Quality Preference slider requires enablement of the  check box found in the  Configure PCoIP image quality levels  ADM GPO variable shown below.   The Image Quality Preference slider (shown below) resides in the OSD under …